Note: Do not replace any controllers until you have followed the POST (ISPR) error
procedures (see POST (ISPR) error procedureson page 71).). Replace a
ServeRAID controller only when indicated to do so in the POST (ISPR) error
procedures.
XXX in Table 12 is used as a placeholder and may be any letter or number in an
actual error message.
Table 12. ServeRAID-4x problems and actions
Problem Action
1XXX (Microcode Checksum Error) ServeRAID-4 controller
2XXX thru 5XXX (Code DRAM Error) 1. Install download jumpers, flash latest
level BIOS and firmware for controller.
Remove jumpers.
2. ServeRAID-4 controller
6XXX (Cache DRAM Error) (ServeRAID-4H
only)
1. Reseat Daughter card
2. Install download jumpers, flash latest
level BIOS and firmware for controller.
Remove jumpers.
3. ServeRAID-4 controller
7XXX thru 8XXX (Host/Local PCI Bus
Interface Error)
1. Install download jumpers, flash latest
level BIOS and firmware for controller.
Remove jumpers.
2. ServeRAID-4 controller
9ZXX thru BZXX SCSI Bus error caused by
cables, termination, defective drives, and so
on). The Z refers to the specific channel or
channels that cause the error.
1. Follow indications in the POST error
procedures (see POST (ISPR) error
procedureson page 71). Follow those
instructions before continuing with the
next steps listed in this table.
2. SCSI cable
3. SCSI backplane
4. Hard drive
5. ServeRAID-4 controller
EFFE (Firmware code corrupt or download
jumpers are in place)
1. Flash latest level BIOS and firmware for
controller. Remove jumpers.
2. ServeRAID-4 controller
FFFF or other code not listed 1. Follow indications in the POST (ISPR)
error procedures (POST (ISPR) error
procedureson page 71).
2. SCSI cable
3. SCSI backplane
4. Hard drive
5. ServeRAID-4 controller
Testing the ServeRAID 4x adapter
You can run all diagnostic operations for the ServeRAID adapters through the IBM
ServeRAID Configuration software in the Advanced Functions option. You can run
subsystem diagnostics through the system diagnostics.
Note: Before running any test, back up the current disk array configuration using
the ServeRAID diagnostics test program. Always keep a current backup of
the ServeRAID configuration information. Dynamic changes may occur in the
configuration due to hot-spare replacement.
Chapter 7. Troubleshooting 73