IBMeServerhttp://www-1.ibm.com/support/docview.wss?rs=1201&uid=psg1SCOD-3ZVQ5W&loc=en_US&cs=utf-8&lang=eAugust 8, 2006Configuration an
x COG Notes:1. Available only as standard equipment in an IntelliStation workstation model or configured to order via CTO.2. See IntelliStation sy
92 COG 25P2889 06P3601 1526 10/100 Ethernet Server Adapter - - - -31P9605 39Y6105 1512 PRO/1000 MT Server Ethernet Adapter by IntelHalf 64-bit/
Chapter 7. xSeries 226 93 Notes:1. xSeries 226 does not have any Active-PCI slots.2. Currently only one type of RAID is supported at a time; for
94 COG Figure 19. xSeries 226 rear view
Chapter 7. xSeries 226 95xSeries 226 power and accessories Notes:1. Nonredundant power models include a single 530w nonhot-swap power supply a
96 COG SBB NumberOption NumberFeature Code DescriptionRacks- 93061RX - NetBay11 Standard Rack Cabinet- 9306250 - NetBay25 Standard Rack Cabinet-
Chapter 7. xSeries 226 97 Keyboard and Mouse02R3206 31P7415 8800 Preferred Pro Full-size Keyboard - 104 Keys, business black- 31P8950 - USB Keybo
98 COG Notes:1. USB accessories are not compatible with the NetBay console switches. They attach to a single USB-capable server.2. Includes a 1
Chapter 7. xSeries 226 99xSeries 226 tape options SBB NumberOption NumberFeature Code Tape DrivesBays Supported1Storage Interface Form FactorE
100 COG SBB NumberOption NumberFeature Code Tape DrivesBays Supported1Storage Interface Form FactorExt Tape Encl49P3228 48P7042 5354 20/40GB TR
Chapter 7. xSeries 226 101Notes:1. Installation may require removing a standard device.
© Copyright IBM Corp. 2003, 2006 3Chapter 1. IntelliStation M Pro 6218 Table 2. IntelliStation M Pro 6218 At-A-GlancePart Number1CPU/FSB Speed (GH
102 COG
© Copyright IBM Corp. 2003, 2006 103Chapter 8. xSeries 236 Table 17. xSeries 236 At-A-GlancePart Number1Withdrawal Date2CPU/FSB Speed (GHz/MHz) - C
104 COG Notes:1. Model numbers provided are worldwide generally available variant (GAV) model numbers which are not orderable as listed and need t
Chapter 8. xSeries 236 1053. Intel Xeon processor with Extended Memory 64 Technology (EM64T), L2 cache and an 800MHz (quad-pumped) Front Side Bus
106 COG xSeries 236 memory options Notes:1. Quantity two of each SBB PN must be ordered to equal its corresponding option.2. Supports Chipkill.
Chapter 8. xSeries 236 107 Figure 20. xSeries 236 system boardxSeries 236 internal cablingxSeries 236 models are cabled internally with a sing
108 COG xSeries 236 hard disk drive (HDD) and optical storage options Notes:1. Bays 1 and 2 can be converted to support three additional HDDs fo
Chapter 8. xSeries 236 109 Notes:1. Bays 1 and 2 can be combined to support one full-high device.2. The optional Ultra320 3-Pack HDD Kit conve
110 COG xSeries 236 I/O options SBBNumberOptionNumberFeatureCode DescriptionAdapterLengthPCISupportSlotsSupportedHotPlugStorage Controllers02R099
Chapter 8. xSeries 236 111 Notes:1. Ultra320 Internal Single-drop 24” LVD SCSI Cable option is required when connecting internal HDDs to ServeRAI
4 COG 6218-47Y 3.6/800/ 2M-L21/12GB/4GBATI FireGL V7100Tower 1GB SCSI Fixed 73GB/900GB48/32/48/16X Combo Drive1/35/46218-48Y 3.4/800/ 4M-L21/12GB/4
112 COG xSeries 236 power and accessories Notes:1. xSeries 236 ships with a single 670w hot-swap capable power supply and line cord. A second ho
Chapter 8. xSeries 236 113 Notes:1. Rack kit is 24in deep.SBBNumberOptionNumberFeatureCode DescriptionRacks- 93061RX - NetBAY11 Standard Rack
114 COG 2. USB accessories are not compatible with the NetBay console switches. They attach to a single USB-capable server.3. Includes a 15in flat
© Copyright IBM Corp. 2003, 2006 115Chapter 9. xSeries 306m Table 19. xSeries 306m At-A-GlancePart Number1, 2Withdrawal Date3CPU/FSB Speed (GHz/MH
116 COG 8849-G2Y- Intel Pentium D Processor 920 (2.8GHz/4MB)Dual Core 1/11GB/8GBRack(1U)1/1-NDual1GbSATA Simple-Swap0GB/500GBCDROM 24x-10x2/22/2884
Chapter 9. xSeries 306m 1178491-10Y-Intel Pentium 4 Processor 531 with EM64T (3.0 GHz 1M L2)1/1512MB/8GBRack(1U)1/1-NDual1GbSATA Simple-Swap0GB/
118 COG Notes:1. Model numbers provided are worldwide generally available variant (GAV) model numbers which are not orderable as listed and need t
Chapter 9. xSeries 306m 119xSeries 306m memory options Notes:1. The server comes with one 512 MB DIMM installed in DIMM connector 1. If on
120 COG xSeries 306m hard disk drive (HDD) and optical storage options Notes:1. Mixing of different HDD technologies is not supported. SBBNu
Chapter 9. xSeries 306m 121xSeries 306m I/O options SBBNumberOptionNumberFeature Code DescriptionAdapterLengthPCISupportSlotsSupportedStorage
Chapter 1. IntelliStation M Pro 6218 5 Notes:1. Model numbers provided are worldwide generally available variant (GAV) model numbers which are no
122 COG Notes:1. The optional ServeRAID -7t SATA controller can be installed only in PCI-X slot 2. The low-profile bracket that comes with the con
Chapter 9. xSeries 306m 123xSeries 306m power and accessories Option Number PowerPower Distribution Units26K4241 DPI 32A Single Phase C13 Ente
124 COG Notes:1. Converts KVM signals for CAT5 cabling for servers with PS/2 KVM ports.SBBNumberOptionNumberFeature Code DescriptionRack Consol
Chapter 9. xSeries 306m 125xSeries 306m tape options Notes:1. This option contains: option part number of single drive - 39M5656 and option pa
126 COG
© Copyright IBM Corp. 2003, 2006 127Chapter 10. xSeries 336The xSeries 336 is housed in a 19in rack-mountable drawer and also provides three USB por
128 COG Notes:1. Model numbers provided are worldwide generally available variant (GAV) model numbers which are not orderable as listed and need t
Chapter 10. xSeries 336 1299. Capacities are based on installation of two 3.5-in 146 GB Ultra320 or four 2.5-in 73 GB Ultra320 HDDs (SCSI models)
130 COG xSeries 336 memory options Notes:1. Quantity two of each SBB PN must be ordered to equal its corresponding option.2. Supports Chipkill.
Chapter 10. xSeries 336 131Figure 24. xSeries 336 system boardxSeries 336 internal cablingHot-swap SCSI modelsxSeries 336 hot-swap SCSI models ar
6 COG IntelliStation M Pro 6218 processor options IntelliStation M Pro 6218 memory options Notes:1. Memory DIMMs must be installed in pairs.
132 COG xSeries 336 hard disk drive (HDD) and optical storage options SBB NumberOption NumberFeature Code Description HeightBays Supported1Max Qt
Chapter 10. xSeries 336 133 Notes:1. Installation may require removing standard devices.2. Mixing SATA and SCSI HDDs is not supported.3. These HD
134 COG Figure 26. xSeries 336 Front ViewxSeries 336 I/O options SBB NumberOptionNumberFeature Code DescriptionAdapter LengthPCI SupportSlots Su
Chapter 10. xSeries 336 135 Notes:1. xSeries 336 does not have any Active-PCI slots.2. Support is for tape only. Tape support requires the PCI sl
136 COG xSeries 336 power and accessories Option Number DescriptionPower190P5280 585w Hot-Swap Power SupplyPower Distribution Units39Y8923 DPI 6
Chapter 10. xSeries 336 137Notes:1. xSeries 336 ships with a single 585w hot-swap capable power supply, a rack power cable and line cord. A secon
138 COG Notes:1. USB accessories are not compatible with the NetBay console switches. They attach to a single USB-capable server.2. Includes a 15i
Chapter 10. xSeries 336 139xSeries 336 tape options Notes:1. This option contains: option part number of single drive - 39M5656 and option par
140 COG
© Copyright IBM Corp. 2003, 2006 141Chapter 11. xSeries 346The xSeries 346 is housed in a 19in rack-mountable drawer and also provides three USB por
Chapter 1. IntelliStation M Pro 6218 7 Figure 1. M Pro 6218 system boardTable 3. Standard Memory ConfigurationModel Std. DIMM Configuration10Y, 1
142 COG 8840-0RY - 2.8/ 800 2MB L2 1 / 21GB / 16GB Rack (2U)1 / 2PHFYDual 1GbD u a l U320Hot-swap0/1800GBCD/DVD R/W (24x)8 / 64 / 48840-1RY -
Chapter 11. xSeries 346 143 Notes:1. Model numbers provided are worldwide generally available variant (GAV) model numbers which are not orderable
144 COG xSeries 346 memory options Notes:1. Quantity two of each SBB PN must be ordered to equal its corresponding option.2. Supports Chipkill.
Chapter 11. xSeries 346 145Figure 28. xSeries 346 system boardxSeries 346 internal cablingxSeries 346 models are cabled internally with a single,
146 COG xSeries 346 hard disk drive (HDD) and optical storage options SBBNumberOptionNumberFeatureCode Description HeightBaysSupported1Max QtyFlo
Chapter 11. xSeries 346 147 Notes:1. Installation may require removing standard devices.2. These HDDs are supported on machine type 8840-E2Y.3. A
148 COG xSeries 346 I/O options SBBNumberOptionNumberFeatureCode DescriptionAdapterLengthPCI SupportSlotsSupportedHotPlug1Storage Controllers39R8
Chapter 11. xSeries 346 149 Notes:1. xSeries 346 does not have any Active-PCI slots.2. Supported for external attachment only and not for interna
150 COG xSeries 346 power and accessories Notes:1. Non-redundant power models ship with a single 625w hot-swap capable power supply, a rack powe
Chapter 11. xSeries 346 151 Notes:1. USB accessories are not compatible with the NetBAY console switches. They attach to a single USB-capable
8 COG IntelliStation M Pro 6218 hard disk drive (HDD) and optical storage options SBB NumberOption NumberFeature CodeDescription HeightBays Suppo
152 COG xSeries 346 tape options Option Number Tape DriveBays SupportedStorage Interface Form FactorExt Tape Encl-----Tape Autoloaders87691VX 1U
© Copyright IBM Corp. 2003, 2006 153Chapter 12. System x3400 (7973, 7974) Notes:1. Model numbers provided are worldwide generally available varia
154 COG System x3400 (7973, 7974) processor options Notes:1. One additional processor may be installed, providing a maximum of two. All processo
Chapter 12. System x3400 (7973, 7974) 155System x3400 (7973, 7974) hard disk drive (HDD) and optical storage options SBBNumberOptionNumbe
156 COG System x3400 (7973, 7974) I/O options SBBNumberOptionNumberFeature Code DescriptionAdapter LengthPCI SupportSlots SupportedHot-Plug
Chapter 12. System x3400 (7973, 7974) 157System x3400 (7973, 7974) power and accessories OptionNumber DescriptionPower--Power Distribution Uni
158 COG OptionNumber DescriptionRack and NetBAY93072RX IBM 25U Standard Rack 93074RX IBM 42U Standard Rack93074XX IBM 42U Standard Rack Extensi
Chapter 12. System x3400 (7973, 7974) 159System x3400 (7973, 7974) tape options SBBNumberOptionNumberFeature Code Tape DriveBaysSupportedStora
160 COG
© Copyright IBM Corp. 2003, 2006 161Chapter 13. System x3400 (7975, 7976) Table 28. System x3400 (7975, 7976) At-A-Glance Part Number1CPU/FSB Spee
Chapter 1. IntelliStation M Pro 6218 9 Notes:1. A maximum of three HDDs for SAS or SCSI models or four SATA HDDs in SATA models are supported. Th
162 COG Notes:1. Model numbers provided are worldwide generally available variant (GAV) model numbers which are not orderable as listed and need t
Chapter 13. System x3400 (7975, 7976) 163System x3400 (7975, 7976) processor options Notes:1. One additional processor may be installed, provi
164 COG SBB NumberOption Number Feature code Memory Description1, 2Memory Cards13M7285 13M7409 4219 4-DIMM DDR2 MEMORY CARD3Memory DIMMs73P
Chapter 13. System x3400 (7975, 7976) 165 Figure 31. x3400 (7975, 7976) system boardTable 30. 8-DIMM Configuration in mirrored modeNumber of D
166 COG System x3400 (7975, 7976) hard disk drive (HDD) and optical storage options SBBNumberOptionNumberFeatureCodeDescription HeightBays
Chapter 13. System x3400 (7975, 7976) 167System x3400 (7975, 7976) I/O options SBBNumberOptionNumberFeatureCode DescriptionAdapterLengthPCI
168 COG - 17001RS - TotalStorage DS400 - Single Controller-- - -- 17002RD - TotalStorage DS400 - Dual Controller-- - -- 17012RD - TotalStorage DS30
Chapter 13. System x3400 (7975, 7976) 169 73P4005 73P4001 1509 NetXtreme 1000 SX Fiber Ethernet Adapter 23Half 64-bit/133MHz1 ... 6 -73P4105
170 COG System x3400 (7975, 7976) power and accessories Option Number DescriptionPower- -Power Distribution Units39Y8905 DPI NEMA Rack PDU 39Y89
Chapter 13. System x3400 (7975, 7976) 171 Option Number DescriptionRack and NetBAY141042X IBM Linux Cluster Rack93072RX IBM 25U Standard Rack
10 COG Figure 2. M Pro 6218 front viewBay Form Factor Height Front Access Usage15.25HHYesStd. Optical2 5.25 HH Yes Optical/Tape /SATA HDD/ SCSI HD
172 COG System x3400 (7975, 7976) tape options SBB NumberOption NumberFeature Code DescriptionRack and NetBAY- - - Refer to Rack Cabinets and
Chapter 13. System x3400 (7975, 7976) 173 71P9176 71P9145 5355 36/72GB DDS Generation 5 Tape Drive2...3 - - -Tape Autoloaders---- - ---
174 COG
© Copyright IBM Corp. 2003, 2006 175Chapter 14. System x3500 Table 31. System x3500 At-A-Glance Part Number1CPU/FSB Speed (GHz/MHz)-CacheNumber of
176 COG Notes:1. Model numbers provided are worldwide generally available variant (GAV) model numbers which are not orderable as listed and need t
Chapter 14. System x3500 177 31R3775 - 0651 Intel Xeon Processor 7020 3RY31R3777 - 0652 Intel Xeon Processor 7040 4RYSBB NumberOption NumberFeatu
178 COG System x3500 memory options Notes:1.Pairs are not required to match. SBB NumberOption NumberFeature Code Memory DescriptionMemory
Chapter 14. System x3500 179 Table 33. 12-DIMM Configuration in non-mirrored modeNumber of DIMMs DIMM Slots1121, 44 1, 4, 7, 106 1, 4, 7,
180 COG Figure 32. x3500 system board
Chapter 14. System x3500 181System x3500 hard disk drive (HDD) and optical storage options SBBNumberOptionNumberFeature Code Description H
Chapter 1. IntelliStation M Pro 6218 11IntelliStation M Pro 6218 I/O options IntelliStation M Pro 6218 power and accessories SBB NumberO
182 COG Notes:1. Hot-Swap SAS/SATA HDDs are installed in the order of Bay 11 as standard then Bay 10, 9, 8,7,6,5,4.. System x3500 I/O options
Chapter 14. System x3500 183 39Y6096 39Y6093 1489 NetXtreme 1000 T + Dual Port Ethernet AdapterHalf 32/64-bit 4 ... 6 -39Y6101 39Y6098 1486 Ne
184 COG - 17421xx - TotalStorage DS4400 Midrange Disk System (all models)-- - -- 17421RX - DS4400 Midrange Disk System - - - -- 17241XX - Total
Chapter 14. System x3500 185 PCI Slot 5 PCI-X 64-bit - - 133 - - -PCI Slot 6 PCI-32-bit - - 33 - - -RSA SL Socket - - - - - - -ServeRAID --- - -
186 COG System x3500 power and accessories SBBNumberOptionNumberFeature Code DescriptionPower39Y8326 39Y8487 0942 Redundant Power and Cooli
Chapter 14. System x3500 187 Option Number DescriptionRack and NetBAY93072RX 25U Standard Rack 93074RX 42U Standard Rack 93074XX 42U Standa
188 COG System x3500 tape options - 17352LX - 2x16 Local Console Manager- 17354GX - 4x16 Global Console ManagerMonitors- 90P0717 - L150p 15in b
Chapter 14. System x3500 189 SBB NumberOption NumberFeature Code Tape DriveBays SupportedStorage InterfaceForm FactorExt Tape Enclosures- 59P6
190 COG
© Copyright IBM Corp. 2003, 2006 191Chapter 15. System x3550 Table 35. System x3550 At-A-Glance Part Number1CPU/FSB Speed (GHz/MHz)-CacheNumber of
1Twentieth Edition (August 2006)© Copyright International Business Machines Corporation 2003, 2006. All rights reserved.US Government Users Restricte
12 COG IntelliStation M Pro 6218 tape options SBBNumberOptionNumberFeatureCode DescriptionMonitors25R4183 49387NX 7601 IBM C117 17" (15.9i
192 COG Notes:1. Model numbers provided are worldwide generally available variant (GAV) model numbers which are not orderable as listed and need t
Chapter 15. System x3550 193System x3550 processor options Notes:1. One additional processor may be installed, providing a maximum of two.
194 COG System x3550 memory options SBBNumberOptionNumberFeatureCode Memory DescriptionMemory DIMMs 39M5780 - 0546 512MB PC2-5300 CL5 ECC DD
Chapter 15. System x3550 195Figure 33. x3550 system board
196 COG System x3550 hard disk drive (HDD) and optical storage options SBBNumberOption NumberFeatureCode Description HeightBays SupportedMaximu
Chapter 15. System x3550 197 Notes:1. Hot-Swap SAS/SATA HDDs are installed in the order of Bay 11 as standard then Bay 10, 9, 8,7,6,5,4.. S
198 COG System x3550 I/O options Notes:1.The ServeRAID 8k SAS Controller comes standard and provides Raid 0, 1 and 10.2. A PCI-X Riser Card must
Chapter 15. System x3550 199 SBB NumberPart NumberFeature Code DescriptionAdapter LengthPCI SupportSlots SupportedHot-Plug Capable1Storage Cont
200 COG System x3550 power and accessories - 2005H08 - TotalStorage Fibre Channel Switch H08-- - -- 2005H16 - TotalStorage Fibre Channel Swi
Chapter 15. System x3550 201 Notes:1. System x3500 ships with a single 670w hot-swap capable power supply, a rack power cable and line cord. A se
Chapter 1. IntelliStation M Pro 6218 13 SBB NumberOption NumberFeature Code Tape DrivesBays Supported1Storage Interface Form FactorExt Tape En
202 COG 17352GX IBM Global 2x16 Console Manager17354GX IBM Global 4x16 Console Manager17231RX IBM 1U 17" Flat Panel Console Kit w/ Optical
Chapter 15. System x3550 203 System x3550 tape options OptionNumberDescriptionBays SupportedStorage InterfaceForm FactorExt Tape EnclosureT
204 COG - 17226LU - DS4300 Midrange Disk (6LU) - - - -- 17226LX - DS4300 Midrange Disk (6LX) - - - -- 17226XX - TotalStorage DS4300 Midrange Disk S
Chapter 15. System x3550 205
206 COG
© Copyright IBM Corp. 2003, 2006 207Chapter 16. System x3650 Table 36. System x3650 At-A-Glance Part Number1CPU/FSB Speed (GHz/MHz)-CacheNumber of
208 COG Notes:1. Model numbers provided are worldwide generally available variant (GAV) model numbers which are not orderable as listed and need t
Chapter 16. System x3650 209System x3650 processor options Notes:1. One additional processor may be installed, providing a maximum of two. All
210 COG System x3650 memory options Notes:1. A minimum of one DIMM is required. However, for performance, a minimum of two identical DIMMs shoul
Chapter 16. System x3650 211System x3650 hard disk drive (HDD) and optical storage options System x3650 I/O options SBB NumberOption Number
212 COG Notes:1. A PCI-X riser is required when installing a PCI-X adapter in either slot 1 or slot 2.2. A PCI-E riser is required when installing
Chapter 16. System x3650 213 Notes:1. System x3650 ships with a single power supply. A second hot-swap power supply is optional for redundancy.
214 COG System x3650 tape options 17352LX IBM 2x16 Local Console Manager17351GX IBM 2x8 Local Console Manager17351LX IBM 1x8 Local Console Mana
© Copyright IBM Corp. 2003, 2006 215Chapter 17. System x3650 T Notes:1. Model numbers provided are worldwide generally available variant (GAV) mo
216 COG System x3650 T processor options Notes:1. One additional processor may be installed, providing a maximum of two. All processors must be
Chapter 17. System x3650 T 217System x3650 T I/O options SBB NumberPart Number DescriptionAdapter LengthPCI SupportSlots SupportedHot-Plug Cap
218 COG
© Copyright IBM Corp. 2003, 2006 219Chapter 18. System x3800 and xSeries 260 Table 38. System x3800 and xSeries 260 At-A-GlancePart Number1Machine
220 COG 8865-4TYx3800 Intel Xeon Processor 7020 2.67/6672x1MB L2 Cache Dual Core 1/42GB/32GBRack (7U)2/3PHFSYDual 1GBSAS Hot-swap0GB/3600GB16X DVD
Chapter 18. System x3800 and xSeries 260 221 Notes:1. Model numbers provided are worldwide generally available variant (GAV) model numbers which
© Copyright IBM Corp. 2003, 2006 15Chapter 2. IntelliStation Z Pro 6223IntelliStation Z Pro (6223) provides six USB ports (two front/four rear), two
222 COG System x3800 and xSeries 260 processor options Notes:1. Three additional processors may be installed, providing a maximum of four. All p
Chapter 18. System x3800 and xSeries 260 223System x3800 and xSeries 260 memory options Notes:1. The customer can choose up to a total of (4)
224 COG Figure 35. x3800 and x260 DIMMsTable 40. Standard Memory ConfigurationModel Std. DIMM Configuration11Y, 1RY, 21Y, 2RY 2 x 1GB PC2-3200
Chapter 18. System x3800 and xSeries 260 225System x3800 and xSeries 260 hard disk drive (HDD) and optical storage options Notes:1. The option
226 COG Figure 36. x3800 and x260 front viewBay Form Factor Height Front Access Usage1HSSLYOPEN2HSSLYOPEN3HSSLYOPEN4HSSLYOPEN5HSSLYOPEN6HSSLYOP
Chapter 18. System x3800 and xSeries 260 227System x3800 and xSeries 260 I/O options Notes:1. Internal tape drives are only supported with thi
228 COG SLOT Type BusVoltage (V)Frequency MHzData PathActive PCI? (Hotswap)Slot LengthScan SequenceDevice NumberPCI Slot 1 PCI-X 2.02 Universal
Chapter 18. System x3800 and xSeries 260 229System x3800 and xSeries 260 power and accessories Notes:1. System x3800 and xSeries 260 ship stan
230 COG Notes:1. Converts KVM signals for CAT5 cabling for servers with PS/2 KVM ports.2. Provides hardware needed to convert the tower unit in
Chapter 18. System x3800 and xSeries 260 231System x3800 and xSeries 260 tape options Notes:1. A minimum of 1 FH and a maximum of 2 HH tape dr
16 COG 6223-52Y- 3.4/800 2MB L22/21GB/16GB3DLabs Wildcat Realizm 800Mini-tower1GB U320 Fixed SCSI73GB/587.2GBCD-RW/DVD (48x-32x-48x-16x)6/46/56223-
232 COG
© Copyright IBM Corp. 2003, 2006 233Chapter 19. System x3850 and xSeries 366The System x3850 and xSeries 366 is housed in a 3U high, 19in rack-mount
234 COG 8863-E9Y x3850 3.16/ 667 1M L2 Cache0M L3 Cache1/42GB/64GBRack(3U)2/2PSHFMYDual1GBSAS Hot-Swap0GB/438GBUltralight DVD-ROM Ultrabay Enhanced
Chapter 19. System x3850 and xSeries 366 235 Notes:1. Model numbers provided are worldwide generally available variant (GAV) model numbers which
236 COG 11. 8863-EAY ships standard with four memory card adapters.12. Models 8863-3RY, 8863-4RY, 8863-3SY, and 8863-EAY ship with a dual core proc
Chapter 19. System x3850 and xSeries 366 237System x3850 and xSeries 366 memory options Notes:1. x3850 and x366 support Chipkill, memory mirro
238 COG Figure 37. x3850 and x366 DIMMsFigure 38. x3850 and x366 performance sensitive configurationsFigure 39. x3850 and x366 cost sensitive confi
Chapter 19. System x3850 and xSeries 366 239System x3850 and xSeries 366 hard disk drive (HDD) and optical storage options Notes:1. Installat
240 COG Figure 41. x3850 and x366 front viewFigure 42. x3850 and x366 operator information panelBay Form Factor Height Front Access Usage12.5in
Chapter 19. System x3850 and xSeries 366 241System x3850 and xSeries 366 I/O options SBBNumberOptionNumberFeatureCode DescriptionAdapter Length
Chapter 2. IntelliStation Z Pro 6223 17 6223-5BY- 3.4/8002MB L21/22GB/8GBNVIDIA Quadro FX 1400Mini-tower1GB U320 Fixed SATA73GB/ 587.3GBCD-RW/DVD
242 COG Notes:1. Six 64-bit Active PCI-X 2.0 slots per chassis.2. Option 17429xx may be subject to a rack installation/configuration fee.3. IXA Ad
Chapter 19. System x3850 and xSeries 366 243 Figure 43. x3850 and x366 rear viewSlot/Device Type Bus Voltage (V)Frequency MHzData Path Active
244 COG System x3850 and xSeries 366 power and accessories Notes:1. System x3850 and xSeries 366 ship with a single 1300W hot-swap capable power
Chapter 19. System x3850 and xSeries 366 245 Notes:1. Refer to the Rack Console Options section for information regarding console connectivity
246 COG System x3850 and xSeries 366 tape options SBBNumberOptionNumberFeature Code Tape DriveBays SupportedStorage InterfaceForm FactorExt Tape
© Copyright IBM Corp. 2003, 2006 247Chapter 20. System x3950 and xSeries 460 Notes:1. Model numbers provided are worldwide generally available va
248 COG following nomenclature: xxU. For example, the U.S. orderable part number for 8872-1RY is 8872-1RU. See the product specific Official IBM an
Chapter 20. System x3950 and xSeries 460 2492. These processor options support up to 32-socket (64-cores) SMP applications in the System x3950 an
250 COG Notes:1. Two memory cards come standard. The first memory card has 2x1GB memory DIMMs installed. The second memory card is open. A tot
Chapter 20. System x3950 and xSeries 460 251Figure 44. x3950 and x460 DIMMSSystem x3950 and xSeries 460 hard disk drive (HDD) and optical storage
18 COG Notes:1. Model numbers provided are worldwide generally available variant (GAV) model number which are not orderable as listed and need to b
252 COG Notes:1. Installation may require removing standard devices.2. All models ship standard with an Ultralight DVD-ROM Ultrabay Enhanced. S
Chapter 20. System x3950 and xSeries 460 253Figure 45. x3950 and x460 front viewSystem x3950 and xSeries 460 I/O options SBBNumberOptionNumberF
254 COG External Disk Systems and Options- 17226xx - DS4300 Midrange Disk (60U) - - - -- 17001RS - TotalStorage DS400 - Single Controller----- 1700
Chapter 20. System x3950 and xSeries 460 255 32P9296 22P7801 1501 NetXtreme 1000 SX Fiber Ethernet----System Management39Y9567 39
256 COG Notes:1. Option 39R8816 and option 39R8815 are supported for external attachment only and not for internal HDDs. 2. The x3950 and x460 sup
Chapter 20. System x3950 and xSeries 460 257Figure 46. x3950 and x460 rear viewFigure 47. x3950 and x460 system board
258 COG System x3950 and xSeries 460 power and accessories Notes:1. For runtimes and UPS attributes, see Appendix C: UPS Runtime Estimate.2.
Chapter 20. System x3950 and xSeries 460 259 SBBNumberOptionNumberFeatureCode DescriptionRack/Tower Conversion Kits39Y8069 32P1636 3772
260 COG - 90P0721 - IBM L170p 17" TFT Monitor (Hybrid)- 90P0726 - IBM C170 17" CRT Monitor- 49387NU - IBM C117 17" CRT Monitor-
Chapter 20. System x3950 and xSeries 460 261 Notes:1. Refer to the Rack Console Options section for information regarding console connectivity us
Chapter 2. IntelliStation Z Pro 6223 19 IntelliStation Z Pro 6223 memory options Notes:1. Quantity two of each SBB PN must be ordered to eq
262 COG System x3950 and xSeries 460 tape options SBBNumberOptionNumberFeatureCode DescriptionBays SupportedStorage InterfaceForm FactorExt T
Chapter 20. System x3950 and xSeries 460 263 - 4559FHX - 2U Full High Stand Alone SCSI Tape Drive Enclosure- Ultra160 (16-bit)Desktop or Rack She
264 COG
© Copyright IBM Corp. 2003, 2006 265Chapter 21. Datacenter solution program The IBM Datacenter Solution Program is a comprehensive set of hardware,
266 COG Scalability/enablement memory card option x460 or x3950 Datacenter solutions containing 16 processors or greater require one Scalability En
Chapter 21. Datacenter solution program 267Datacenter solutions
268 COG x3950 and x460 scalable diagramsNote: The following sample configurations are for illustration only and may not be suitable for any specifi
Chapter 21. Datacenter solution program 269Figure 50. 2 Node, 32-way ConfigurationMXE 460MXE 460MXE 460MXE 460MXE 460MXE 460MXE 460xSeries 460Fib
270 COG Single node Datacenter high availability solutionsThe Datacenter High Availability (HA) Program Offering delivers a fully configured, Datac
Chapter 21. Datacenter solution program 271Scalability kit513M7414 2.3m Scalability Cable 0 2 3 613M7416 2.9m Scalability Cable 0 0 3 6Select app
20 COG Figure 3. Z Pro 6223 System BoardTable 6. Standard Memory ConfigurationModel Std. DIMM Configuration10Y 2 x 256MB PC2-3200 ECC DDR2 SDRAM R
272 COG Notes:1. All final customer configurations and solutions require IBM Solution Assurance Approval.2. The Datacenter OS comes preloaded on e
Chapter 21. Datacenter solution program 273Multi-node Datacenter high availability solutionsThe Datacenter High Availability (HA) Program Offerin
274 COG Select appropriate expansion enclosure588741AY x3950 E with 4-way 32-bit HA COA 2 4 6 12 14 2888741BY x3950 E with 4-way 64-bit HA COA 2 4
Chapter 21. Datacenter solution program 275 Notes:1. All final customer configurations and solutions require IBM Solution Assurance Approval.2. M
276 COG 12. Memory can be installed using one of two methodologies: Performance installation or cost-effective installation. Performance installati
Chapter 21. Datacenter solution program 27739Y6079 NetXtreme 1000 TxG Ethernet Adapter Can be installed in models 88727AY, 88727BY, 88728AY, 8872
278 COG Notes:1. All final customer configurations and solutions require IBM Solution Assurance Approval. 2. Software subscriptions for the Datace
Chapter 21. Datacenter solution program 279Datacenter scalable solutionsThe Datacenter Scalable Program Offering delivers a Datacenter Solution t
280 COG Select appropriate expansion enclosure488741DY x3950 E with 4-way 32-bit Scalable COA 0 1 3 788741EY x3950 E with 4-way 64-bit Scalable COA
Chapter 21. Datacenter solution program 281 Notes:1. All final customer configurations and solutions require IBM Solution Assurance Approval.2. T
Chapter 2. IntelliStation Z Pro 6223 21IntelliStation Z Pro 6223 hard disk drive (HDD) and optical storage options Notes:1. May require removi
282 COG upgraded, the new system model type must be registered with IBM. Directions for registering the new system model type are included in the o
Chapter 21. Datacenter solution program 2834818HAX Software Update Subscription for Microsoft Windows Server 2003 Datacenter Edition, 64-bit, 4 p
284 COG Notes:1. All final customer configurations and solutions require IBM Solution Assurance Approval.2. A maximum of two ServeRAID 8i controll
Chapter 21. Datacenter solution program 285Manufacturing configuration servicesRequired service offerings are manufacturing install fees associat
286 COG
© Copyright IBM Corp. 2003, 2006 287Chapter 22. eServer 326m Table 53. eServer 326m At-A-GlancePart Number1CPU/FSB Speed (GHz/MHz) - Cache2Number
288 COG 7969-67Y 2.2/1000 1MB L2Opteron Processor Model 275Dual Core2/24GB/16GBRack(1U)1/1- Y 1GB U320 Hot-Swap72.8GB/600GB-73/22/27969-68Y 2.2/100
Chapter 22. eServer 326m 289 Notes:1. Model numbers provided are worldwide generally available variant (GAV) model numbers which are not orderabl
290 COG eServer 326m processor options Notes:1. Microprocessor SMP upgrades must be of the same type and clock speed. Mixing microprocessors of
Chapter 22. eServer 326m 291 Figure 51. eServer 326m DIMMseServer 326m internal SCSI cablingHot-Swap SCSI modelseServer 326m hot-swap models cont
© Copyright IBM Corp. 2003, 2006 iiiContentsSummary of Changes . . . . . . . . . . . . . . . . vInformation sources . . . . . . . . . . . . . . .
22 COG Notes:1. Standard HDD is installed in bay 6.Figure 4. Z Pro 6223 Front ViewIntelliStation Z Pro 6223 Bay UsageBay Form Factor Height Fro
292 COG eServer 326m hard disk drive (HDD) and optical storage options SBBNumberOptionNumberFeatureCode Description HeightBaysSupported Max
Chapter 22. eServer 326m 293eServer 326m I/O options SBBNumberOptionNumberFeature Code DescriptionAdapterLengthPCISupportSlotsSupportedHot Plug
294 COG Notes:1. If a Remote Supervisor Adapter is selected, then PCI-X Riser, SBB 32R2287, is required. The PCI-X Adapter must be plugged into sl
Chapter 22. eServer 326m 295eServer 326m power and accessories SBBNumberOptionNumberFeatureCode DescriptionPower--- -Power Distribution Un
296 COG eServer 326m tape options Notes:1. Supported externally only.SBBNumberOptionNumberFeatureCode DescriptionBaysSupportedStorageInterfaceFo
© Copyright IBM Corp. 2003, 2006 297Chapter 23. BladeCenter® T 8720 Notes:1. The Management Module incorporates a chassis-level management proces
298 COG BladeCenter T 8720 optical storage options Figure 52. BladeCenter T 8720 front viewBladeCenter T 8720 cabling options SBBNumberOpt
Chapter 23. BladeCenter® T 8720 299 Notes:1. This cable is 1.5m in length and provides four connections between the optical pass-thru-module (OPM
300 COG Figure 54. IBM BladeCenter Optical Pass-thru Module SC Cable (1.5M)This cable provides connection between the Optical Pass-thru Module and
Chapter 23. BladeCenter® T 8720 301Figure 57. IBM CX4 1.5 or 3.0 meter Cable for IBM BladeCenter (Connector color is Gray)BladeCenter T 8720 I/O
Chapter 2. IntelliStation Z Pro 6223 23IntelliStation Z Pro 6223 I/O options Notes:1. Currently only one type of RAID is supported at a time;
302 COG Notes:1. Mixing Ethernet (including Copper Pass-thru Module (CPM)) and Fibre/SAN switches in I/O module bays 3 and 4 is not supported. How
Chapter 23. BladeCenter® T 8720 303Figure 58. BladeCenter T 8720 modulesBladeCenter T 8720 power and accessories Table 57. BladeCenter Sta
304 COG
© Copyright IBM Corp. 2003, 2006 305Chapter 24. BladeCenter® T 8730 Notes:1. The Management Module incorporates a chassis-level management proces
306 COG BladeCenter T 8730 optical storage options Figure 59. BladeCenter T 8730 front viewBladeCenter T 8730 cabling options SBB NumberOption
Chapter 24. BladeCenter® T 8730 307 Notes:1. This cable is 1.5m in length and provides four connections between the optical pass-thru-module (OPM
308 COG Figure 61. IBM BladeCenter Optical Pass-thru Module SC Cable (1.5M)This cable provides connection between the Optical Pass-thru Module and
Chapter 24. BladeCenter® T 8730 309Figure 64. IBM CX4 1.5 or 3.0 meter Cable for IBM BladeCenter (Connector color is Gray)BladeCenter T 8730 I/O
310 COG Notes:1. When installed in switch module bay 3, port 1 is enabled on blade-installed Fibre Channel expansion cards. When installed in swit
Chapter 24. BladeCenter® T 8730 311Figure 65. BladeCenter Telco 8730 modulesBladeCenter T 8730 power and accessories SBB NumberOption NumberF
24 COG Figure 5. Z Pro 6223 Rear View
312 COG
© Copyright IBM Corp. 2003, 2006 313Chapter 25. BladeCenter® chassis 8677 Notes:1. Model number is a worldwide general available variant (GAV) mo
314 COG Figure 66. 8677 front viewBladeCenter chassis 8677 optical storage options BladeCenter chassis 8677 cabling options Table 61. Blad
Chapter 25. BladeCenter® chassis 8677 315 Notes:1. This cable is 1.5m in length and provides four connections between the optical pass-thru-modul
316 COG Figure 68. IBM BladeCenter Optical Pass-thru Module SC Cable (1.5M)This cable provides connection between the Optical Pass-thru Module and
Chapter 25. BladeCenter® chassis 8677 317Figure 71. IBM CX4 1.5 or 3.0 meter Cable for IBM BladeCenter (Connector color is Gray)BladeCenter chass
318 COG Notes:1. Mixing Ethernet (including Copper Pass-thru Module (CPM)) and Fibre/SAN switches in I/O module bays 3 and 4 is not supported. How
Chapter 25. BladeCenter® chassis 8677 319Figure 72. 8677 rear viewFigure 73. 8677 switch module bays
320 COG Figure 74. 8677 management module baysBladeCenter chassis 8677 power and accessories Table 62. BladeCenter Standard Power Configura
© Copyright IBM Corp. 2003, 2006 321Chapter 26. BladeCenter® H 8852 Notes:1. Model number is a worldwide general available variant (GAV) model nu
Chapter 2. IntelliStation Z Pro 6223 25IntelliStation Z Pro 6223 power and accessories Notes:1. IntelliStation Z Pro 6223 includes a 530w volt
322 COG Figure 75. BladeCenter H 8852 front viewBladeCenter H 8852 optical storage options Notes:1. Only the read function is supported on t
Chapter 26. BladeCenter® H 8852 323BladeCenter H 8852 cabling options Notes:1. This cable is 1.5m in length and provides four connections betw
324 COG Figure 76. IBM BladeCenter Copper Pass-thru Module Cable This IBM BladeCenter option provides connection between the copper pass-thru modul
Chapter 26. BladeCenter® H 8852 325Figure 79. InfiniBand 4x Cable 3 meter for IBM BladeCenter Figure 80. IBM CX4 1.5 or 3.0 meter Cable for IBM B
326 COG 32R1863 32R1860 1495 Nortel Networks L2/L3 Copper Gigabit Ethernet Switch Module for IBM BladeCenter- - 3, 4 Y 232R1864 32R1861 1496 Nortel
Chapter 26. BladeCenter® H 8852 327 Notes:1. Mixing Ethernet (including Copper Pass-thru Module (CPM)) and Fibre/SAN switches in I/O module bays
328 COG Figure 81. BladeCenter H 8852 rear view
Chapter 26. BladeCenter® H 8852 329BladeCenter H 8852 power and accessories Notes:1. Two power cords are required.Table 65. BladeCenter H
330 COG
© Copyright IBM Corp. 2003, 2006 331Chapter 27. BladeCenter® HS20 - 7981 Notes:1. This model is a 32-bit platform only. 64-bit operating systems
26 COG Notes:1. IntelliStation Z Pro 6223 ships standard with an IBM 104-key keyboard and three-button mouse.SBB NumberOption NumberSBB Number
332 COG HS20 - 7981 processor options Notes:1. If two processors are installed they must have the same core frequency, Front Side Bus frequency
Chapter 27. BladeCenter® HS20 - 7981 333HS20 - 7981 memory options Notes:1. The memory subsystem is a 2-way interleaved subsystem; memory must
334 COG HS20 - 7981 hard disk drive (HDD) storage options Notes:1. Installation of a second SFF SAS HDD will physically prevent installation of
Chapter 27. BladeCenter® HS20 - 7981 335HS20 - 7981 I/O options Notes:1. Quantity one expansion card is supported inside the blade itself. In
© Copyright IBM Corp. 2003, 2006 337Chapter 28. BladeCenter® HS20 - 8843The HS20 - 8843 requires that the BladeCenter chassis have 2000w power suppl
338 COG Notes:1. Model numbers provided are worldwide generally available variant (GAV) model numbers which are not orderable as listed and need t
Chapter 28. BladeCenter® HS20 - 8843 339HS20 - 8843 processor options Notes:1. One additional processor may be installed, providing a maximum
340 COG Notes:1. This system is preloaded with Microsoft® Windows® Storage Server 2003, Non-Cluster Version (1-4 Proc Version) (Standard Block Mode
Chapter 28. BladeCenter® HS20 - 8843 341 Notes:1. Installation of a second HDD will physically prevent installation of certain expansion card
Chapter 2. IntelliStation Z Pro 6223 27IntelliStation Z Pro 6223 tape options Notes:1. Installation may require removing a standard device.SBB
342 COG HS20 - 8843 I/O options SBB NumberOption NumberFeatureCode DescriptionForm FactorBlade Server Expansion Cards 1, 226K4837 73P6000 15
Chapter 28. BladeCenter® HS20 - 8843 343 Notes:1. Quantity one expansion card is supported inside the blade itself. The optional expansion unit w
344 COG
© Copyright IBM Corp. 2003, 2006 345Chapter 29. BladeCenter® HS21 - 8853 Notes:1. Model numbers provided are worldwide generally available varian
346 COG 6. An integrated, single-channel, SAS controller supports integrated RAID-0 and 1. RAID-1E and 5 requires the optional BladeCenter Storage
Chapter 29. BladeCenter® HS21 - 8853 347HS21 - 8853 memory options HS21 - 8853 hard disk drive (HDD) storage options Notes:1. RAID-1E and 5
348 COG HS21 - 8853 I/O options Notes:1. Comes standard with option 39R7563.SBBNumberOptionNumberFeatureCode DescriptionFormFactorStorage Contr
© Copyright IBM Corp. 2003, 2006 349Chapter 30. BladeCenter® HS40 Notes:1. Blade server models xTx are designed to support the telecommunications
350 COG HS40 processor options Notes:1. Up to three additional processors may be installed, providing a maximum of four. All processors must be
Chapter 30. BladeCenter® HS40 351HS40 I/O options Notes:1. Two identical expansion cards are allowed. Each installed expansion card will physi
28 COG
352 COG
© Copyright IBM Corp. 2003, 2006 353Chapter 31. BladeCenter® JS20 Notes:1. 2-way blade server installs in a BladeCenter chassis. KVM support is n
354 COG JS20 memory options Notes:1. DIMMs are installed in matched pairs using the following population order: DIMM3 & DIMM4, DIMM1 & D
Chapter 31. BladeCenter® JS20 355JS20 I/O options Notes:1. One expansion card is allowed per blade server and installs over IDE HDD bay 2, pre
© Copyright IBM Corp. 2003, 2006 357Chapter 32. BladeCenter® JS21 JS21 memory options Table 75. BladeCenter JS21 At-A-GlancePart NumberCPU/FSB
358 COG Notes:1. The installed DIMMs on a JS21 Blade must all be PC2-3200 (400MHz DDR2) or all PC2-4300 (533MHz DDR2), a mix is not supported. Mem
Chapter 32. BladeCenter® JS21 359JS21 hard disk drive (HDD) storage options Notes:1. Up to two SAS HDDs may be installed in each JS21.Figure 8
360 COG JS21 I/O options Notes:1. If this expansion card is selected, a second hard drive cannot be selected. SBBNumberOptionNumberFeatureCod
© Copyright IBM Corp. 2003, 2006 361Chapter 33. BladeCenter® LS20 Notes:1. Model numbers provided are worldwide generally available variant (GAV)
© Copyright IBM Corp. 2003, 2006 29Chapter 3. IntelliStation Z Pro 9228 Table 7. IntelliStation Z Pro 9228 At-A-GlancePart Number1CPU/FSB Speed (G
362 COG GAV to MTM mapping for AP Geographies follow the same pattern. Substitute the last character with a country-specific designator.2. The LS20
Chapter 33. BladeCenter® LS20 363LS20 memory options SBBNumberOptionNumberFeatureCode Description73P5136 - 0520 512MB PC2700 CL3 ECC DDR S
364 COG Figure 91. LS20 system boardLS20 hard disk drive (HDD) storage options SBBNumberOptionNumberFeatureCode Description HeightBaysSupportedM
Chapter 33. BladeCenter® LS20 365LS20 I/O options Notes:1. Quantity one expansion card is supported inside the blade itself. Installation of
366 COG
© Copyright IBM Corp. 2003, 2006 367Chapter 34. Blade server storage and I/O expansion Notes:1. Embedded support is provided for RAID levels 0 an
368 COG Figure 93. BladeCenter Storage and Expansion Unit 3, View 2Figure 94. BladeCenter Storage and Expansion Unit 3, View 3
Chapter 34. Blade server storage and I/O expansion 369 Notes:1. PCI adapter options for the BladeCenter PCI I/O Expansion Unit. PCI adapters i
370 COG
© Copyright IBM Corp. 2003, 2006 371Chapter 35. VMware offeringsNote: VMware support is required when purchasing VMware software.Virtual machine sof
30 COG Notes:1. Model numbers provided are worldwide generally available variant (GAV) model numbers which are not orderable as listed and need to
372 COG Notes:1. Orderable only when configured with an xSeries server, not separately.2. When ordering VMware ESX Server 2 products, the latest 2
Chapter 35. VMware offerings 373Virtual Infrastructure management software for environments using VMware ESX Server. Table 82. VMware VirtualCe
374 COG Notes:1. A VirtualCenter add-on that enables live servers to be moved from one virtual machine host to another.2. A VirtualCenter bundle w
Chapter 35. VMware offerings 375Offers resource optimization, high availability and data protection that deliver capabilities not possible with p
376 COG 4817T05 VMware DRS 2 for 2 sockets - 3 year Full Subscription4817U05 VMware DRS 2 for 2 sockets - 5 year Full Subscription4817L05 VMware DR
Chapter 35. VMware offerings 3774817V18 VMware Virtual Desktop Infrastructure (VDI) Standard Pilot Bundle including PSO VDI Pilot, 25 VMs, Virtua
378 COG These BladeCenter license packs and media kits enable you to conveniently purchase VMware software and product media for a full BladeCente
Chapter 35. VMware offerings 379Virtual machine software ideal for x86-based server consolidation, disaster recovery, 2 and streamlining software
380 COG The following servers are compatible with VMware ESX Server 2.x, ESX 2.x upgrades, Virtual SMP and Virtual SMP Upgrades. • IBM provides
© Copyright IBM Corp. 2003, 2006 381Chapter 36. xSeries network operating system offeringsIBM Systems Group offers a range of Network Operating Syst
Chapter 3. IntelliStation Z Pro 9228 31IntelliStation Z Pro 9228 processor options Notes:1. If 1 CPU only, install in CPU1 location2. When ins
382 COG 32R1025 MS Storage Server 2003 - Non Cluster - (1-4 proc) X2 32R1026 MS Storage Server 2003 - Non Cluster - (1-4 proc) X2
Chapter 36. xSeries network operating system offerings 38332R2744 Red Hat Enterprise Linux ES 3 AMD64/EM64T with 1 yr Red Hat Network, preloaded
384 COG 25K7966 Red Hat Enterprise Linux AS 3 Standard x86 with 1 yr Red Hat support, preloaded XX XX 25K7967 Red Hat Enterprise Linux
Chapter 36. xSeries network operating system offerings 38532P9577 Red Hat Enterprise Linux ES 3 Standard x86 with 3 yr Red Hat Network, preloaded
386 COG 39Y5308 Red Hat Enterprise Linux AS 4 with 1 yr Premium Red Hat Support (CD)3X X XX XX X XXXXX X XX39Y5310 Red Hat Enterprise Linux ES 4 wi
Chapter 36. xSeries network operating system offerings 38739R7022 Red Hat Enterprise Linux ES 4 with 1 yr Subscription (32-bit, preinstalled)XX X
388 COG 31R1437 SUSE Linux Enterprise Server 9 1-16 CPUs for 3 years (CD)3X X XX XX X XXXXX X XX40K1392 SUSE Linux Enterprise Server 9 for BladeCen
Chapter 36. xSeries network operating system offerings 38932R2642 SUSE Linux Enterprise Server 9 1 yr Subscription per additional 8 Cluster Nodes
390 COG 40K1510 Red Hat Enterprise Linux 4 1 yr standard subscription, 8 Cluster Nodes XX40K1511 Red Hat Enterprise Linux 4 1 yr standard subscrip
Chapter 36. xSeries network operating system offerings 391Notes:1. Orderable only when configured with an xSeries server or IntelliStation workst
iv COG Chapter 40. TotalStorage DS300 disk system . . . . . . . . . . . . . . . . . . . . . . . . . . 413Chapter 41. TotalStorage DS400 disk system
32 COG Figure 6. Z Pro 9228 memory DIMMs
392 COG
© Copyright IBM Corp. 2003, 2006 393Chapter 37. IBM and third party software applicationsCheck with your IBM representative to verify application so
394 COG Table 89. Application Workload ManagerApplication Workload Manager for IBM DirectorFeatures Include: • Tools to manage contending s
Chapter 37. IBM and third party software applications 395 Table 91. Remote Deployment ManagerRemote Deployment ManagerFeatures Include:• R
396 COG Table 93. Altiris Deployment SolutionAltiris Deployment Solution for ServersFeatures Include: • Comprehensive server deployment for bot
Chapter 37. IBM and third party software applications 397 Table 94. SteelEye LifeKeeper High Availability Clustering SoftwareSteelEye LifeKeepe
398 COG 39Y5177 LifeKeeper Extender for Windows24R9484 MS IIS 5.0 Web Server Module24R9485 SQL Server Module24R9486 DB2 WE, EE, EEE, ESE Modul
Chapter 37. IBM and third party software applications 399 Table 96. VERITAS Cluster Server and Storage Foundation SolutionsARMTech 2.x Active R
400 COG 4812M9X Cluster Server for NetApp SnapMirror, Windows, Advanced/Enterprise Edition, v4.3, License, with no support4812C9X Cluster Server fo
Chapter 37. IBM and third party software applications 4014812FJX Dynamic Multipathing (DMP) Option, Windows, Advanced/Enterprise Edition, v4.3, L
Chapter 3. IntelliStation Z Pro 9228 33IntelliStation Z Pro 9228 hard disk drive (HDD) and optical storage options SBBNumberOptionNumberFeatur
402 COG 4812FWX HA Enterprise Option, Windows, Advanced/Enterprise Edition, v4.3, License, with extended support4812MXX HA Enterprise Option, Windo
Chapter 37. IBM and third party software applications 4034812N7X Hardware Replication Agent for IBM PPRC, Windows, Datacenter, v4.3, License, wit
404 COG 4812GPX Storage Foundation HA, Windows, Server/Standard/Web Edition, v4.3, License, with extended support4812NQX Storage Foundation, Window
Chapter 37. IBM and third party software applications 4054812E2X Cluster Server, Global Cluster Option, Linux, Per CPU, v4.1, License, with exten
406 COG 4812BFX Storage Foundation Cluster File System Enterprise HA, Linux, Per CPU, v4.1, License, with basic support4812EFX Storage Foundation C
Chapter 37. IBM and third party software applications 4074812ESX Cluster Server, Linux, Apache HTTP, Per CPU, v4.0, License, with extended suppor
408 COG 4812F2X Storage Foundation Cluster File System Enterprise, Linux, Red Hat EL 3.0 (IA-32), Per CPU, v4.0, License, with extended support481
© Copyright IBM Corp. 2003, 2006 409Chapter 38. EXP400 storage expansion unit Notes:1. Includes a single 2m Ultra2 SCSI cable and dual hot-swap
410 COG EXP400 hard disk drive (HDD) storage options Notes:1. EXP400 Storage Expansion Unit ships with 14 slim-line hot-swap bays which can be co
© Copyright IBM Corp. 2003, 2006 411Chapter 39. EXP420 storage expansion unit Notes:1. Includes two 4Gbps SW SFPs, dual hot-swap 600w redundant
34 COG Figure 7. Z Pro 9228 front viewBay Form Factor Height Front Access Usage1 5.25 inch - N/A CD ROM2 5.25 inch - N/A CD/Tape3 Diskette Dri
412 COG EXP420 hard disk drive (HDD) storage options EXP420 other options Option NumberDescription Height Bays SupportedMaximum QuantitySATA HD
© Copyright IBM Corp. 2003, 2006 413Chapter 40. TotalStorage DS300 disk system Notes:1. Not available from IBM after this date. Business Partner
414 COG Notes:1. Maximum number of host ports and redundant host connections requires upgrading to dual controllers.TotalStorage DS300 hard dis
Chapter 40. TotalStorage DS300 disk system 415Notes:1. DS300 model 1RL in its base configuration supports seven HDDs. Installation of eight or mo
416 COG TotalStorage DS300 other options Notes:1. Hardware iSCSI initiator which installs into a supported server and connects via ethernet cabl
© Copyright IBM Corp. 2003, 2006 417Chapter 41. TotalStorage DS400 disk system Notes:1. Not available from IBM after this date. Business Partner
418 COG 6. Also includes four 146GB HDDs, four short-wave SFP modules, four DS4000 Host Bus Adapters and four 5m LC-LC Fibre Channel cables.7. Also
Chapter 41. TotalStorage DS400 disk system 419TotalStorage DS400 hard disk drive (HDD) storage Notes:1. External options may require software u
420 COG TotalStorage DS400 other options Notes:1. Installs into a supported server and connects via fibre channel cabling directly to the DS400
© Copyright IBM Corp. 2003, 2006 421Chapter 42. TotalStorage DS4100 disk system Table 105. TotalStorage DS4100 Disk System At-A-GlanceName Part N
Chapter 3. IntelliStation Z Pro 9228 35IntelliStation Z Pro 9228 I/O options Notes:1. The SAS daughter card is required for all SAS configurat
422 COG Notes:1. Not available from IBM after this date. Business Partner Inventory may be available.2. DS4100 ships with the rail mounting kit and
Chapter 42. TotalStorage DS4100 disk system 423TotalStorage DS4100 hard disk drive (HDD) storage Notes:1. External options may require softwar
424 COG Notes:1. Licensed one per DS4100.2. Available for DS4100 Dual Controller only.3. Designed to connect a 1Gb device or cable to a 2Gb device
© Copyright IBM Corp. 2003, 2006 425Chapter 43. System Storage DS4200 disk system Notes:1. DS4200 Model 7V provides two RAID controllers with 1GB
426 COG System Storage DS4200 hard disk drive (HDD) storage Notes:1. External options may require software upgrades, licenses, etc. Refer to the
Chapter 43. System Storage DS4200 disk system 427 Notes:1. Option includes two 4Gbps SW SFPs.42D3272 DS4200 16-64 Storage Partition Upgrade 126K7
428 COG
© Copyright IBM Corp. 2003, 2006 429Chapter 44. TotalStorage DS4300 disk system Table 109. TotalStorage DS4300 Disk System At-A-GlanceName Part Nu
430 COG Notes:1. DS4300 - Single Controller provides a single, low-cost RAID controller and can be upgraded to DS4300 - Dual Controller. Ships wit
Chapter 44. TotalStorage DS4300 disk system 431 Notes:1. Ships with a single Default Host Group which does not provide storage partitioning ca
36 COG IntelliStation Z Pro 9228 power and accessories SBBNumberOptionNumberFeatureCode DescriptionPower Supplies and Power Cord OptionsPower Dis
432 COG TotalStorage DS4300 hard disk drive (HDD) storage Notes:1. External options may require software upgrades, licenses, etc. Refer to the “
Chapter 44. TotalStorage DS4300 disk system 433TotalStorage DS4300 other options Option Number Description Max Qty24P8149 DS4300 1st EXP700 Att
434 COG Notes:1. License to attach 15 to 28 HDDs.2. License to attach 29 to 42 HDDs.3. License kit upgrade to support up to 42 HDDs.4. License to
© Copyright IBM Corp. 2003, 2006 435Chapter 45. TotalStorage DS4500 disk system Notes:1. DS4500 provides two RAID controllers with 1GB Cache each
436 COG Figure 95. FAStT900 storage serverTotalStorage DS4500 hard disk drive (HDD) storage Notes:1. External options may require software upgra
Chapter 45. TotalStorage DS4500 disk system 437TotalStorage DS4500 other options Notes:1. Licensed one per DS4500.2. Requires Storage Manager
438 COG
© Copyright IBM Corp. 2003, 2006 439Chapter 46. TotalStorage DS4700 disk system Notes:1. DS4700 Model 70 provides two RAID controllers with 1GB C
440 COG TotalStorage DS4700 hard disk drive (HDD) storage Notes:1. External options may require software upgrades, licenses, etc. Refer to the “
Chapter 46. TotalStorage DS4700 disk system 441TotalStorage DS4700 other options Notes:1. Licensed one per DS4700.2. Option includes two 4Gbps
Chapter 3. IntelliStation Z Pro 9228 37 - 93072SX - IBM 25U Standard Rack- 93074EX - IBM 42U Standard Rack Extension- 93074RX - IBM 42U Standard
442 COG
© Copyright IBM Corp. 2003, 2006 443Chapter 47. TotalStorage DS4800 disk system Notes:1. DS4800 Model 80H provides two RAID controllers with 2GB
444 COG Notes:1. DS4800 ships standard with eight SFP's which can be used in any of the Host Ports or Expansion Ports. Up to eight additio
Chapter 47. TotalStorage DS4800 disk system 445TotalStorage DS4800 other options Notes:1. Licensed one per DS4800.2. Option includes two 4Gbps
446 COG
© Copyright IBM Corp. 2003, 2006 447Chapter 48. TotalStorage DS4000 EXP100 storage expansion unit Notes:1. Attachment to a supported Storage Serv
448 COG TotalStorage DS4000 EXP100 hard disk drive (HDD) options TotalStorage DS4000 EXP100 other options Notes:1. Designed to connect a 1Gb
© Copyright IBM Corp. 2003, 2006 449Chapter 49. TotalStorage DS4000 EXP710 fibre channel storage expansion unit Notes:1. Attachment to a supporte
450 COG TotalStorage DS4000 EXP710 hard disk drive (HDD) options TotalStorage DS4000 EXP710 other options Option Number Description Height Ba
© Copyright IBM Corp. 2003, 2006 451Chapter 50. TotalStorage DS4000 EXP810 storage expansion unit Notes:1. Attachment to a supported Storage Serv
38 COG
452 COG TotalStorage DS4000 EXP810 hard disk drive (HDD) options TotalStorage DS4000 EXP810 other options Option Number Description Height Ba
© Copyright IBM Corp. 2003, 2006 453Chapter 51. Additional fibre channel components Notes:1. Provides 10 ports in a 1/2-rack width, 1U high chass
454 COG Notes:1. Provides 16 ports in a 1U high chassis. Ships standard with eight short-wave 4 Gbps SFP modules, rack power cord and a rail kit.2.
Chapter 51. Additional fibre channel components 455 Notes:1. Provides up to 16 ports in a half-rack width chassis. Ships standard with eight shor
456 COG
© Copyright IBM Corp. 2003, 2006 457Chapter 52. External storage configuration examplesThe following sample configurations are for illustration only
458 COG The following sample configurations are for illustration only and may not be suitable for any specific customer installation. Contact your
Chapter 52. External storage configuration examples 459Figure 99. DS4100 and DS4300 Drive Attach ExamplesHBA 1 HBA 2Host System AHBA 1 HBA 2Host
460 COG Figure 100. DS4500 Host and Drive Attach ExamplesDS45001 Gb/s 2 Gb/sX10X1Tray NumberConflict1 Gb/s 2 Gb/sX10X1Tray NumberConflict1 Gb/s 2 G
© Copyright IBM Corp. 2003, 2006 461Chapter 53. Rack cabinets and options Table 128. Rack CabinetsNetBay11 Standard RackS2 25U Standard RackS2 42U
© Copyright IBM Corp. 2003, 2006 39Chapter 4. IntelliStation A Pro 6217IntelliStation A Pro 6217 also provides an integrated Broadcom 5703ci Gb Ethe
462 COG Notes:1. Conforms to EIA 310 - D Standard 19in rack specification for a Type A cabinet with universal hole spacing.2. Side stabilizer brac
Chapter 53. Rack cabinets and options 463Server system rack alternatives Notes:1. Rack installation requires appropriate conversion kit.2. If
464 COG IBM Rack-Mounted UnitsStandard Power Cords1DescriptionMachineType / ModelSize (U)2Depth (in)Approx Weight3(lbs)3Power (Watts)Typical/Max
Chapter 53. Rack cabinets and options 465 Notes:1. Optional rack power cords: P/N 94G6667 - 14ft NEMA 5-15P; P/N 94G7448 - 14ft IEC 320-C14.2. 1U
466 COG General rack placement rules and other information:• Locate heaviest components at the bottom of the rack (i.e., UPS, then servers or stora
Chapter 53. Rack cabinets and options 467 Rack OptionsOption NumberDescription InformationConsole Support:28L4707 Netfinity Rack Keyboard Tray
468 COG 73P5832 USB Conversion Option Converts the console signals of servers with USB and VGA console ports and cable management arms (on slides)
Chapter 53. Rack cabinets and options 469 2130R30 UPS3000XLV (US) 2U, 120v, 24a, six IEC C13 outlets, 1 NEMA L5-20R outlet, includes L5-20P to L5
470 COG K 2.8 36 36 Left/Right sides of rack to Service Clearance areaL 36 60 60 Front of rack to Service Clearance areaM 30 30 30 Rear of rack to
© Copyright IBM Corp. 2003, 2006 471Chapter 54. Rack console optionsA console consisting of a keyboard, monitor and pointing device is required by e
40 COG 6217-22Y250- 1MB L21/22GB/16GBnVIDIA Quadro FX 1400 Mini-Tower1GB SATA Fixed SATA80GB/1000GB748X/32X/48X/16X Max CD-RW/DVD-ROM 1/46/45/46/56
472 COG Multi-server console switchingRefer to the cable labeling key in the Cable Options table appearing later in this section.
Chapter 54. Rack console options 473Refer to the cable labeling key in the Cable Options table appearing later in this section.
474 COG Notes:1. All switches are RoHS compliant.2. ARI port is an RJ45 connector used to connect servers with appropriate console cables (Opti
Chapter 54. Rack console options 475 Notes:1. Mounts above 2U console (requires 1U of space). Switch Placement RulesMounting Locations LCM2
476 COG Notes:1. Short C2T Interconnect chaining cable standard with the C2T-capable servers.2. C2T Cable Kit (P/N 06P4792) includes a long C2T ch
© Copyright IBM Corp. 2003, 2006 477Chapter 55. xSeries rack power configuratorRack Power Products:Distributed Power Interface (DPI) Power Distribut
478 COG Notes:1. Each device usually comes with a power cord. The PDU requires the power cord to have an IEC 320-C14 plug. Order 39Y7932 (14ft) if
Chapter 55. xSeries rack power configurator 479Typical Rack Power ConfigurationsNotes:1. Each PDU and UPS comes with a country-specific power cor
480 COG Side-wall Compartment ArrangementsNote: The above is intended to show only typical arrangements, not all possible arrangements.CBAUD9308-42
Chapter 55. xSeries rack power configurator 481Country-specific considerations: USA, Canada, parts of Latin America, TaiwanPower Load CapacityPar
Chapter 4. IntelliStation A Pro 6217 416217-47Y254-1MB L22/28GB/16GBnVIDIA Quadro FX 4500 PCIExpress Mini-Tower1GB U320 Fixed SCSI73GB/1200GB848X
482 COG LegendN NEMA PDU with a 12a circuit breakerC Rack PDU with a 15a circuit breakerW FE PDU with a 20a fuse per outletS E PDU with 20a cir
Chapter 55. xSeries rack power configurator 483
484 COG Country-specific considerations: Europe, Africa, Asia Pacific, parts of Latin AmericaPower Load Capacity LegendC Rack PDU with a 15a cir
Chapter 55. xSeries rack power configurator 485Power Load CapacityIEC 309-2P+GCEE7-VIISII 32SABS 164BS 1363 w/fuseCEI 23-16etc.@ country specific
486 COG Country-specific considerations: JapanPower Load Capacity LegendN NEMA PDU with a 12a circuit breakerC Rack PDU with a 15a circuit break
Chapter 55. xSeries rack power configurator 487
488 COG Rack PDU power cablesLegend:1. Device to wall line cord2. Device to PDU/UPS power cable3. Rack PDU to wall line cord4. Rack PDU to Front-en
Chapter 55. xSeries rack power configurator 489PDU power cord plug typesNote: Match letters with Key columns in the following chart to identify p
490 COG PDU power cables Option Part NumberCable Part NumberPlug TypePlug TypeRating (a/v)Cable Length (m/ft)Country/CommentsRack PDUsDPI 100-127
Chapter 55. xSeries rack power configurator 491Front-end PDUsDPI Single-phase 30A Front-end PDU - LV (US)32P1751 74P4314 Burndy Y NEMA L5-30PH 30
© Copyright IBM Corp. 2003, 2006 vSummary of Changes• Versions of this document released on or after August 8th, 2006, will contain references to fe
42 COG Notes:1. Model numbers provided are worldwide generally available variant (GAV) model numbers which are not orderable as listed and need to
492 COG DPI Three-phase 380-415V 32A C19 Enterprise PDU (International)26K4259 25R2552 Burndy Y IEC 309 3P+N+G wyeF 32a/415v4.3m/14ftInternational
© Copyright IBM Corp. 2003, 2006 493Part 2. Appendixes
Appendix A. Internal tape drive attributes 495Appendix A. Internal tape drive attributes LegendFH Full-high - approximate height 81 mm/3.2
496 COG Notes:1. For installation of an internal tape drive into a server, see the appropriate system section.2. 1U rack-mounted enclosure that su
© Copyright IBM Corp. 2003, 2006 497Appendix B. External tape and tape library attributesInstalling tape devices on the same bus as other devices ma
498 COG Notes:1. Data provided is in the syntax of Native/Compressed.2. 3623-2SX ships with an external 3m SCSI cable (0.8mm VHDCI -to- 68pin), a
Appendix B. External tape and tape library attributes 499Tape libraries SCSI Interface and Cable LegendF Female - ExternalMMale - External6
500 COG Notes:1. Transfer rates are for single SCSI channel configurations. Tape Libraries utilizing split library or dual host configurations may
Appendix B. External tape and tape library attributes 501 Notes:1. Transfer rates are for single SCSI channel configurations. Tape Libraries util
Chapter 4. IntelliStation A Pro 6217 43IntelliStation A Pro 6217 processor options Notes:1. Installing a second CPU provides four additional m
502 COG Notes:1. Includes tape library with tape drive, rack mounting hardware, cleaning cartridge, 125V US power cord, rack to PDU power cord,
Appendix B. External tape and tape library attributes 503 Notes:1. Includes tape library with tape drive, rack mounting hardware, one data car
504 COG Notes:1. Includes tape library with tape drive, rack mounting hardware, one data cartridge, one cleaning cartridge, 125V US power cord, an
Appendix B. External tape and tape library attributes 505 Notes:1. Includes tape library with tape drive, rack mounting hardware, one data cartri
506 COG Notes:1. Includes tape library with tape drive, rack mounting hardware, one data cartridge, one cleaning cartridge, 125V US power cord, an
© Copyright IBM Corp. 2003, 2006 507Appendix C. UPS runtime estimate (minutes)Steps to determine UPS runtimes and suitable UPS for desired configura
508 COG Notes:1. This table represents general guidelines for selecting the appropriate UPS based on minimum and typical runtime estimates. A ‘max
Appendix C. UPS runtime estimate (minutes) 509 Notes:1. Data provided by APC. Notes:1. How-to-Read example for 200-240(208): Input VAC is 200
510 COG 2. Battery output may be set to 220, 225, 230 or 240 VAC.3. Country-specific line cords available as options. Notes:1. Data provided by
Appendix C. UPS runtime estimate (minutes) 511 Notes:1. Data provided by Eaton.Table 147. IBM UPS3000HV Runtimes1Number of Battery Packs+0 +1
44 COG IntelliStation A Pro 6217 memory options Notes:1. The memory must be installed in pairs across channels. SBBNumber OptionNumberFeatur
512 COG Notes:1. How-to-Read example for 200-240(208): Input VAC is 200-240 as is the UPS output when electric service is active. When electric
Appendix C. UPS runtime estimate (minutes) 513 Notes:1. Data provided by APC.Table 149. IBM UPS7500XHV, 10000XHV Runtimes1Number of Battery Pa
514 COG Notes:1. How-to-Read example for 200-240(208): Input VAC is 200-240 as is the UPS output when electric service is active. When electric
© Copyright IBM Corp. 2003, 2006 515Appendix D. System management overviewIBM system management solutions allow you to run your business-critical ap
516 COG System management support by server Notes:1. This service processor is integrated into the systemboard.2. This service processor is a PC
Appendix D. System management overview 517System management functional comparison Table 152. Functional Comparison ISMP BMC RSA II RSAII SLFea
518 COG Notes:1. Requires IBM Director Agent2. Available via the ASM interconnect or from customer LAN with RSAII installed.3. Not available on e3
Appendix D. System management overview 519Cabling rules:1. Connect the ASM breakout cable to the RSA adapter in the RSAII-host.2. Using a standar
520 COG 2. RSAII-SlimLine and BMC ManagementNote: RSAII-SlimLine and BMC management do not support a dedicated ASM network. Management access is vi
Appendix D. System management overview 5213. Advanced System Management ScenarioFigure 105. Advanced System Management ScenarioEthernet LANRemote
Chapter 4. IntelliStation A Pro 6217 45Figure 8. A Pro 6217 system board
522 COG
© Copyright IBM Corp. 2003, 2006 523Appendix E. xSeries I/O option attributes Option NumberDescription Adapter LengthPCI Support1Low-profile Capab
524 COG Notes:1. Adapters rated at a lower frequency than the slots in which they are installed will reduce the bus to the frequency of the slowes
Appendix E. xSeries I/O option attributes 5258. Single Channel Ultra320 SCSI Controller (P/N 71P8594) provides a single channel with one 68-pin i
526 COG
© Copyright IBM Corp. 2003, 2006 527Appendix F. BladeCenter® power module upgrade guidelinesThis Technical Update contains information that will hel
528 COG BladeCenter power overviewYour BladeCenter unit is separated into two power domains. Power domain A supports all the BladeCenter modules an
Appendix F. BladeCenter® power module upgrade guidelines 529 Important:The HS40 blade server occupies two adjacent bays. When you complete
530 COG Notes:1. The SCSI Storage Expansion Unit is not available for the LS20 blade server.Upgrade calculationTo determine the power-m
Appendix F. BladeCenter® power module upgrade guidelines 531 Important: If the sum of the power unit values in power domain A is greater than
46 COG IntelliStation A Pro 6217 hard disk drive (HDD) and optical storage options Notes:1. Up to four SATA HDDs are supported with the installa
532 COG DANGERPower distribution unit assessmentIf your calculations indicate that you need to upgrade your power modules, you will also need to re
Appendix F. BladeCenter® power module upgrade guidelines 533 Result:• 7.2 IBM power units < 7.4 IBM power units• Two 1200 W power modules w
534 COG
© Copyright IBM Corp. 2003, 2006 535Appendix G. xSeries DC power and NEBS-compliant models The following models, designed for the telecommunications
536 COG
© Copyright IBM Corp. 2003, 2006 537Important noticesA withdrawal date indicates when an item is no longer available from IBM. Business Partner inve
538 COG ©IBM Corporation 2006. All rights reserved.3039 Cornwallis Rd.Research Triangle Park, NC 27709All the part numbers referenced in this publi
IBM@Printed in USASCOD-3ZVQ5W *07SCOD3ZVQ5W *
Chapter 4. IntelliStation A Pro 6217 47 Notes:1. The installation order for adding additional HDDs depends upon the A Pro model. For SCSI mode
48 COG IntelliStation A Pro 6217 I/O options Notes:1. IntelliStation A Pro 6217 Models with the 3DLabs Wildcat Realizm 800 PCIExpress Video Adap
Chapter 4. IntelliStation A Pro 6217 49 IntelliStation A Pro 6217 power and accessories Notes:1. For runtimes and UPS attributes, see Appen
50 COG
© Copyright IBM Corp. 2003, 2006 51Chapter 5. xSeries 100 Table 11. xSeries 100 At-A-GlancePart Number1Withdrawal Date2CPU/FSB Speed (GHz/MHz) - C
52 COG 8486-EDY- Pentium 4 631 3.0/800 - 2MB EM64T1/1512MB/8GBTower 1/1- N 1Gb SATA Fixed 80GB/ 500GBCombo 5/34/48486-EEY- Pentium 4 631 3.0/800
Chapter 5. xSeries 100 53Notes:1. Model numbers provided are worldwide generally available variant (GAV) model numbers which are not orderable as
54 COG xSeries 100 hard disk drive (HDD) and optical storage options SBB NumberOption NumberFeature Code Description HeightBays SupportedMax
Chapter 5. xSeries 100 55Figure 11. xSeries 100 front viewxSeries 100 I/O options SBBNumberOptionNumberFeatureCode DescriptionAdapterLengthPCIS
56 COG Notes:1. Supports tape backup solutions.xSeries 100 power and accessories Notes:1. Uninterruptible Power Supplies are not supported on R
Chapter 5. xSeries 100 57 xSeries 100 tape options OptionNumber DescriptionRack Console Connectivity17351LX 1x8 Local Console Manager17351GX
58 COG Notes:1. This tape drive contains the following options: option part number of single drive - 39M5656 and option part number 5 Pack DDS Gen
© Copyright IBM Corp. 2003, 2006 59Chapter 6. xSeries 206m Table 13. xSeries 206m At-A-GlancePart Number1, 2Withdrawal Date3CPU/FSB Speed (GHz/MHz
60 COG 8485-A2Y- 2.8/800-1MB L21/1512MB/ 8GBTower 1/1-N1GBSATASimple-Swap0GB/2TB48X-20X CD-ROM Black Internal IDE Drive 4/34/48485-B2Y- 3.0/800-2MB
Chapter 6. xSeries 206m 618485-J2Y- 3.2/800-4MB DC L2 1/11GB/8GBTower 1/1PHN1GBSATA/SASHot-Swap0GB/2TB48X-20X CD-ROM Black Internal IDE Drive 4/3
© Copyright IBM Corp. 2003, 2006 viiInformation sourceshttp://www-1.ibm.com/support/docview.wss?rs=1201&uid=psg1SCOD-3ZVQ5W Table 1. Informati
62 COG 8490-7AY- 2.8/800 - 2x1MB L21/1512MB/8GBTower 1/1-N1GBSATASimple-Swap0GB/2TB48X-20X CD-ROM Black Internal IDE Drive 4/34/48490-8AY- 3.0/800
Chapter 6. xSeries 206m 63 Notes:1. Model numbers provided are worldwide generally available variant (GAV) model numbers which are not orderable
64 COG 3. Not available from IBM after this date. Business Partner Inventory may be available.4. Maximum 8GB of memory is supported via four DIMM s
Chapter 6. xSeries 206m 65Notes:1. A maximum of 8 GB of memory is supported using the four DIMM slots with currently available options. Figure 12
66 COG xSeries 206m hard disk drive (HDD) and optical storage options SBBNumberOptionNumberFeatureCode Description HeightBays Supported Max Q
Chapter 6. xSeries 206m 67 Notes:1. Mixing of different HDD technologies (SATA and SAS) is not supported.2. The xSeries 206m IDE controller suppo
68 COG Figure 13. x206m front viewBay Form Factor Height Front Access Usage1 133mm (5.25in) HH Yes Std. Optical2 133mm (5.25in) HH Yes Optical/Tap
Chapter 6. xSeries 206m 69xSeries 206m I/O options SBBNumberOptionNumberFeatureCode DescriptionAdapterLengthPCISupportSlotsSupportedHot PlugCa
70 COG SBB NumberOption NumberFeature Code DescriptionAdapter LengthPCI SupportSlots SupportedHot Plug CapableMax SupportedStorage Controllers02
Chapter 6. xSeries 206m 71 Notes:1. Support is for SCSI tape drives.bye2. PCI slots 5 and 6 will only be available if SBB 25R7432 is selected.- 3
viii COG Additional URLsTechnical spec sheets (PSREF)www.ibm.com/servers/eserver/xseries/Select Technical spec sheets (PSREF).IBM Datacenter Solut
72 COG Figure 14. x206m rear view
Chapter 6. xSeries 206m 73 Figure 15. x206m system boardSLOT/device Type BusVoltage (V)Frequency MHz Data PathActive PCI? (Hotswap)Slot length
74 COG xSeries 206m power and accessories SBBNumberOptionNumberFeature Code DescriptionPower Distribution Units- 26K4241 - DPI 32A Single Phase C
Chapter 6. xSeries 206m 75 Notes:1. Converts KVM signals for CAT5 cabling for servers with PS/2 KVM ports.Rack/Tower Conversion Kits- 39Y9707 - 5
76 COG xSeries 206m tape options SBBNumberOptionNumberFeatureCode DescriptionBaysSupportedStorageInterfaceFormFactorExt Tape EnclTape Drives139M5
Chapter 6. xSeries 206m 77 - 87651UX - IBM 1U Rackmount Tape Enclosure-- - -- 8767HHX - IBM Half High Tabletop Tape Enclosure-- - -- 8768FHX -
78 COG Notes:1. If two optical drives are selected, a tape drive cannot be selected. If a tape drive is selected then always install in bay 2. If
© Copyright IBM Corp. 2003, 2006 79Chapter 7. xSeries 226 Table 15. xSeries 226 At-A-GlancePart Number1Withdrawal Date2CPU/FSB Speed (GHz/MHz) - C
80 COG 8648-34Y11- 2.8/8002MB L2 1/2512MB/16GBTower 1/1H-1GB Dual U320Hot-swap0GB/1.8TBCDROM(48x-20x)9/76/68648-36Y11- 2.8/8002MB L2 1/2512MB/16GBT
Chapter 7. xSeries 226 818488-4BY- 3.0/800 2MB L2 1/2512MB/16GBTower 2/2P H- 1GB Dual U320Hot-swap 0/1.8TBC D - R O M (48x-20x)9/76/6
© Copyright IBM Corp. 2003, 2006 ixIntelliStation® video adapter selection guide Video Adapter1ImagingDual-head GraphicsMemorySignal WidthResoluti
82 COG Notes:1. Model numbers provided are worldwide generally available variant (GAV) model numbers which are not orderable as listed and need to
Chapter 7. xSeries 226 83 Notes:1. One additional processor may be installed, providing a maximum of two. All processors must be identical in typ
84 COG xSeries 226 memory options SBBNumber1OptionNumberFeatureCode Memory Options90P0870 - 0501 256MB PC2-3200 CL3 ECC DDR-2 SDRAM RDIMM - 7
Chapter 7. xSeries 226 85 Notes:1. Quantity two of each SBB PN must be ordered to equal its corresponding option.2. If xSeries 226 comes standard
86 COG Figure 16. xSeries 226 System BoardxSeries 226 internal cablingHot-swap SCSI modelsxSeries 226 hot-swap SCSI models are cabled internall
Chapter 7. xSeries 226 87xSeries 226 hard disk drive (HDD) and optical storage options SBB NumberOption NumberFeature Code Description HeightB
88 COG External Storage Expansion Units4FormFactor39R6615 17331RU - EXP400 Storage Expansion Unit Rack (3U)- 17401RU - FAStT EXP700 Storage Exp
Chapter 7. xSeries 226 89 Notes:1. May require removing standard devices.2. Four SATA HDDs are supported within the installation of the optional
90 COG Figure 17. xSeries 226 front view (SCSI)Figure 18. xSeries 226 front view (SATA)Bay 1Bay 2Bay 3Bay 5Bay 6Bay 7Bay 8Bay 9Bay 4
Chapter 7. xSeries 226 91xSeries 226 I/O options SBBNumberOptionNumberFeatureCode DescriptionAdapterLengthPCI SupportSlotsSupportedHot-PlugCapab
Kommentare zu diesen Handbüchern