Ibm System Storage Subsystem DS5020 Bedienungsanleitung Seite 120

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 250
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 119
Figure 64 shows an incorrect configuration of a single host with both iSCSI and
Fibre Channel connections.
Important: Do not cable the storage subsystem and host systems as shown in
Figure 64. A storage subsystem with the incorrect storage topology
might appear to be functional, but incorrect cabling can potentially have
unpredictable results.
Figure 65 on page 91 shows an example of a multiple-host, multiple-port,
multiple-switch configuration.
Gigabit
Ethernet
switch
Host with two single-port iSCSI
HBAs and one dual-port Fibre
Channel HBA
DS5020
Fibre
Channel
switch
Controller A Controller B
Fibre
Channel
ports
iSCSI
ports
Fibre
Channel
ports
iSCSI
ports
Fibre
Channel
ports
iSCSI
ports
Figure 64. Example of an incorrect configuration: Single-host, iSCSI and Fibre Channel
90 IBM System Storage DS5020 Storage Subsystem: Installation, User’s, and Maintenance Guide
Seitenansicht 119
1 2 ... 115 116 117 118 119 120 121 122 123 124 125 ... 249 250

Kommentare zu diesen Handbüchern

Keine Kommentare