Figure 123. Changes in Array Configuration
The changes in the array are as follows:
The original hot spare disk in bay 3 changed to status ONL (online).
The faulty disk in bay 5 changed to status DDD (defunct).
We will now make the simulated failed disk the new hot spare disk.
7. Plug the unplugged disk back in.
8. Select Replace a Defunct Drive from the Administration Options menu.
9. Select DDD and press Enter.
A screen like the one in Figure 124 will appear.
Figure 124. RAID Administration - Replace a Defunct Drive
10. Select Show Drive Information to verify whether the process was successful.
A screen like the one in Figure 125 on page 159 will appear.